FireSense - Fire Detection Equipment

Fire Panels   Technical Information


Home
Products
Fire Panels
Addressable
Power Supplies
Full Range
Contact Us

Links
Technical

Addressable Fire Panels

Smoke Detectors

Sounders

......

 

Accessories

1 Man Test

The one man test box has been designed to allow you to test a fire alarm installation with only 1 engineer. 

The box calibrates itself to the specific panel, meaning that it can be used on any conventional fire alarm panel.  Once the box has been calibrated it monitors for a fire condition, and when triggered it shuts off the power to the panel, resetting it.

Connecting the box is simple, simply install it between the panel and the batteries (cables supplied) and remove the power from the panel, the box is ready to go!

 

Picture coming soon.

12Way Zonal relay card

The 12 way zonal relay card allows you to zonally control sounder circuits.  12 Sounder zones can be used per board, and multiple boards can be used for each panel.

You connect the board to the repeater outputs of the panel, and the sounders activate based on the zone in fire.  The board is connected to the sounder output of the panel, so the sounders will only activated when you want them to.

 

NEW Relay Board

The relay card can be used for many things, including mains switching. You can use it as a door magnet switch (if you have a 24V power source.), as a mains switch or just as a simple switch.

You can connect the relay card to the sounder line of a panel, with a mains operated door magnet. You connect the mains into the circuit through the relay.

Another application of the relay card is to use it to trigger another panel. You use the sounder output of one panel and put it into the card. This means that when one panel goes into fire it will trigger the second through the Zone input

 

NEW 4 Way Relay Card

This is a 4 way version of our popular relay card

The relay card can be used for many things, including mains switching. You can use it as a door magnet switch (if you have a 24V power source.), as a mains switch or just as a simple switch.

You can connect the relay card to the sounder line of a panel, with a mains operated door magnet. You connect the mains into the circuit through the relay.

 

2wirerelayboard.jpg (7934 bytes)

 

2 Wire Relay Board

The 2 wire relay board works with the new FireSense concept panel.  The relay activates whenever the it is connected to the sounder/detector loops and the panel goes into fire.

Typical applications

bulletUse to cut of the sound system in a night club when the panel goes into fire
bulletUsed to activate door releases on a 2 wire system.
bulletUsed to activate emergency lights when a 2 wire system is being used.

 

4 way sounder card

The 5 way sounder card can be attached to a fire panel to add 3 additional sounder loops.  This can be mounted inside the panel, or inside it's own box with power supply.

Used for :

Expanding number of sounder loops of a panel.
 

 

 

5 way sounder card

The 5 way sounder card can be attached to a fire panel to add 4 additional sounder loops.  This can be mounted inside the panel.  It can also be used zonally, so sounder loops can be sounded individually, based on what zone is in fire.

Used for :

Expanding number of sounder loops of a panel.
Zonal Sounding
 

 

NEW 5 Way high load sounder card

This is like the standard 5 way sounder card, but can handle more current.  Each sounder circuit can take more sounders, enabling you to expand the sounder circuits on your panel.

The card can be attached to a fire panel to add 4 additional sounder loops.  This can be mounted inside the panel.  It can also be used zonally, so sounder loops can be sounded individually, based on what zone is in fire.

Used for :

Expanding number of sounder loops of a panel.
Zonal Sounding

 

2 way sounder card

The 2 way sounder card can be attached to a fire panel to add an additional sounder loop.  This can be mounted inside the panel.

Used for :

Expanding number of sounder loops of a panel.

 

Timer Board

Typical uses

  1. Avoid false triggering form a pressure switch on sprinkler systems due to water pressure variations
  2. Avoid false triggering from a pulsing class change input
  3. To give delay to shutter operation after the fire panel is triggered into alarm


remoteindicator.jpg (5244 bytes)

Remote Indicator

This remote indicator is connected to the sounder loops of a panel, and lights the led when the panel goes into fire.  There is a buzzer built in as well, which sounds on fire.  You can mute the button by pressing the 'mute' button.

applications:

As a fire indicator, gives visible and audible warning.

 

 

Isolate Key Switch

Details coming soon.

 

 

 

 

 

 

 