1 Man Test
The one man test box has been designed to allow you to
test a fire alarm installation with only 1 engineer.
The box calibrates itself to the specific panel,
meaning that it can be used on any conventional fire alarm panel. Once
the box has been calibrated it monitors for a fire condition, and when
triggered it shuts off the power to the panel, resetting it.
Connecting the box is simple, simply install it
between the panel and the batteries (cables supplied) and remove the power
from the panel, the box is ready to go!
|
| Picture coming soon. |
12Way Zonal relay card
The 12 way zonal relay card allows you to zonally
control sounder circuits. 12 Sounder zones can be used per board, and
multiple boards can be used for each panel.
You connect the board to the repeater outputs of the
panel, and the sounders activate based on the zone in fire. The board
is connected to the sounder output of the panel, so the sounders will only
activated when you want them to.
|
 |
NEW Relay Board 
The relay card can be used for many things, including mains switching.
You can use it as a door magnet switch (if you have a 24V power source.), as
a mains switch or just as a simple switch.
You can connect the relay card to the sounder line of a panel, with a mains
operated door magnet. You connect the mains into the circuit through the
relay.
Another application of the relay card is to use it to trigger another panel.
You use the sounder output of one panel and put it into the card. This means
that when one panel goes into fire it will trigger the second through the
Zone input
|
 |
NEW 4 Way Relay Card
This is a 4 way version of our popular relay card
The relay card can be used for many things, including mains switching. You
can use it as a door magnet switch (if you have a 24V power source.), as a
mains switch or just as a simple switch.
You can connect the relay card to the sounder line of a panel, with a mains
operated door magnet. You connect the mains into the circuit through the
relay. |

|
2 Wire Relay Board 
The 2 wire relay board works with the new FireSense concept panel.
The relay activates whenever the it is connected to the sounder/detector
loops and the panel goes into fire.
Typical applications
 | Use to cut of the sound system in a night club when the panel goes
into fire |
 | Used to activate door releases on a 2 wire system. |
 | Used to activate emergency lights when a 2 wire system is being
used. |
|

 |
4 way sounder card 
The 5 way sounder card can be attached to a
fire panel to add 3 additional sounder loops.
This can be mounted inside the panel, or inside it's own box with power
supply.
Used for :
Expanding number of sounder loops of a panel.
|
| 
|
5 way sounder card 
The 5 way sounder card can be attached to a
fire panel to add 4
additional sounder loops. This can be mounted inside the panel.
It can also be used zonally, so sounder loops can be sounded individually,
based on what zone is in fire.
Used for :
Expanding number of sounder loops of a panel.
Zonal Sounding
|
 |
NEW 5 Way high load sounder card
This is like the standard 5 way sounder card, but can
handle more current. Each sounder circuit can take more sounders,
enabling you to expand the sounder circuits on your panel.
The card can be attached to a fire panel to add
4
additional sounder loops. This can be mounted inside the panel.
It can also be used zonally, so sounder loops can be sounded individually,
based on what zone is in fire.
Used for :
Expanding number of sounder loops of a panel.
Zonal Sounding |
 |
2 way sounder card

The 2 way sounder card can be attached to a
fire panel to add an
additional sounder loop. This can be mounted inside the panel.
Used for :
Expanding number of sounder loops of a panel. |
 |
Timer Board 
Typical uses
- Avoid false triggering form a pressure switch on sprinkler systems
due to water pressure variations
- Avoid false triggering from a pulsing class change input
- To give delay to shutter operation after the fire panel is triggered
into alarm
|
 |
Remote Indicator 
This remote indicator is connected to the sounder loops of a panel, and
lights the led when the panel goes into fire. There is a buzzer built
in as well, which sounds on fire. You can mute the button by pressing
the 'mute' button.
applications:
As a fire indicator, gives visible and audible warning. |
 |
Isolate Key Switch