C-TEC 2 Zone CFP Panel
2 Zone CFP Conventional Fire Alarm Panel
DELIVERY
We always aim to same day dispatch on all orders received before 2.30pm.
TRADE COUNTER
Firesense also offer the ability to collect your order from our trade counter.
LPCB certified to EN54-2/4, C-TEC's CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.
Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.
A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.
Optional repeaters and relay expansion boards also available.
Features
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) and EN54 part 13 certified by Kiwa Telefication.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Two detector zone circuits.
- Four conventional sounder circuits*
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system) and optional CFP relay boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV fire detectors, sounders and visual alarm devices.
| Approval | EN54-2, EN54-4, EN54-13 |
|---|---|
| Category Type | Panel |
| IP Rating | IP30 |
| System Type | Conventional |
| Clearance | No |
| Approvals/certifications | Certified to EN54-2 & 4 by the LPCB. Certified to EN54-13 by Kiwa Telefication |
| Mains Supply | 230V 50/60Hz |
| Mains Rated current | 350mA maximum |
| Internal Power Supply | 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault) |
| Total Output Current limited to | 1.5A @ 230Vac (lmaxA eq 146mA) |
| Quiescent current | 25mA (mains failed, internal sounder active, PSU & gen fault LED lit) |
| Max battery size and type | 2 x 12V 3.2Ah VRLA connected in series. Min battery size 1.2Ah. |
| No. of detection zone circuits | 2 (max length per circuit is 500m) |
| Call poit resistor value | 470to 680Ω |
| Max. devices per detector zone | 25 detectors (or 32 detectors/manual call points combined) |
| No. of conventional sounder circuits | 4 (max length per circuit is 500m) |
| EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
| Alarm voltage | 27V max, 20V min (final battery voltage) |
| Max sounder output current | 4 x 200mA (800mA total) |
| Auxiliary relays | Two: (1) Aux. Fire; (2) Fault. Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
| Open collector outputs | Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit volt |
| Other outputs | 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed) |
| Auxiliary inputs | Two: (1) ‘Class Change’ (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching) |
| Engineer (AL3) functions | Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) |
| Expansion connections | Yes – for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards |
| Product dimensions (mm) | 380 W x 235 H x D 96mm (hole required for flush mounting = 367 W x 220 H x 75 D mm. No bezel required). |
| Construction and finish | Plastic lid and base; RAL7035 textured |
| IP rating | IP30 |
| Weight | 1.75kg (without batteries |
| Operating conditions/temperature | -5°C to +40°C. Max relative humidity: 95% |