Ajax FireProtect 2 AC (CO) Jeweller - White
FireProtect 2 AC Wireless mains powered fire detector with CO sensors, with non replaceable lithium back up battery, CR-2/3AZ
DELIVERY
We always aim to same day dispatch on all orders received before 2.30pm.
TRADE COUNTER
Firesense also offer the ability to collect your order from our trade counter.
FireProtect 2 AC is a mains-powered detector designed for residential fire safety. The carbon monoxide sensor alarms before the concentration level becomes threatening. Everything meets the latest fire safety standards. Thought-out design, improved mounting panel with WAGO 221 connectors, and in-app settings make the installation process nice and easy, giving an ultimate experience for PRO.
| Category Type | Detector |
|---|---|
| Colour | White |
| Detection | Carbon Monoxide |
| System Type | Domestic |
| Clearance | No |
Communication
| Jeweller communication technology |
Propreitary wireless technology for transmission of alarms and events. Features:
|
| Radio frequency bands |
866.0 – 866.5 MHz Depends on the region |
| Maximum effective radiated power (ERP) |
up to 20 mW Automatic power control to reduce power consumption and radio interference |
| Radio signal modulation | GFSK |
| Radio communication range |
up to 1,700m Between the detector and a hub (or radio signal range extender) in an open space |
| Encryption of radio communication | All the data stored and transmitted are protected by block encryption with a floating key |
| Radio frequency hopping | To prevent radio interference and jamming |
Sensitive elements
| Sensor | CO (carbon monoxide sensor) |
Carbon monoxide (CO) detection
| Sensitive element | Chemical CO sensor |
| Alarm if accumulated dose of CO is exceeded |
more than 50 ppm (0.005%) — no more than in 90 minutes CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute. |
| Sensor life | 10 years |
Additional features
| In built siren |
Volume 85dB at a distance of 3 metres. Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification |
| Interconnected fire detectors alarms |
Via primary interconnection If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps. via fallback interconnection1 At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub. 1 Fallback interconnected alarm is available only for FireProtect 2 detectors with firmware version 5.59.2.ХХ or later. Devices that support the fallback interconnected alarm are marked on the package with a “Fallback interconnect supported” label. |
| LED indication |
Green is a power indication A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291. Yellow is an indication of malfunctions A LED indicator on the device enclosure lights up when malfunctions are detected. For example, in the case of discharged batteries, contamination of the smoke chamber, or end of the service life. Red is an indication of fire alarms A LED indicator on the device enclosure lights up when the detector registers a fire alarm. |
| Button on the front panel of the detector | In normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, the pressing turns off the detector sound notification. |
| External power supply |
110-240V ~, 50/60Hz The phase and neutral cables from the external power supply should be connected to the WAGO terminals on SmartBracket mounting panel. To remove the detector from SmartBracket, there is no need to disconnect the power cables |
Anti-sabotage protection
| Tampering alarm | Notifications on attempts to detach the detector from the surface or remove it from the mounting panel. |
| Protection against spoofing | Device authentication |
| Detection of communication failure |
Within 15 minutes. The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings). The polling interval is fixed at 300 seconds. |
Power supply
| Main | 110-240V ~, 50/60Hz Up to 2W of mains power consumption |
| Backup | 1 non- replaceable lithum battery CR-2/3AZ. Allows the detector to operate autonomously without the main power source |
Enclosure
| Dimesions | 122 x 122 x54 mm |
| Weight | 304g |
| Operating temeperature range | from 0°C to +50°C |
| Operating humidity | up to 80% |
Colours
| Available in | Black and White |
Complete set
| Contains |
FireProtect 2 AC (CO) Jeweller SmartBracket mounting panel WAGO 221 3 conductor terminal - 2 pcs. (Pre installed in SmartBracket) Installation kit Quick Start Guide |