Ajax FireProtect 2 AC (Heat) Jeweller - Black

In stock
Product Code
107290.173.BL1
SKU
107290.173.BL1

Ajax FireProtect 2 AC (Heat) Jeweller - Black

Wireless mains-powered fire detector with heat sensor

DELIVERY

We always aim to same day dispatch on all orders received before 2.30pm.

Read more about our delivery policy

TRADE COUNTER

Firesense also offer the ability to collect your order from our trade counter. 

Read more about our trade counter

FireProtect 2 AC (Heat) Jeweller

Wireless mains-powered fire detector with heat sensor

Against invisible threats

FireProtect 2 AC is a mains-powered detector designed for residential fire safety. Two thermistors quickly react to the synthetic materials’ burning. Everything meets the latest fire safety standards. Thought-out design, improved mounting panel with WAGO 221 connectors, and in-app settings make the installation process nice and easy, giving an ultimate experience for PRO.

Key Features

  • Two types of interconnected fire alarm 
    • Primary via Ajax Hub, alarm within 20 s
    • Fallback via detector-detector, alarm within 60 s
  • Heat sensors
    • 10 two thermistors
  • Main power supply 
    • 110-240 V~
    • Backup battery
  • Easy wiring with WAGO 221
  • 85 dB built-in siren
  • Remote control and configuration 
  • Informative push notifications
  • Up to 1,700 m communication range with an Ajax hub in open space 
  • Jeweller radio communication 
  • Two colours 
    • Black
    • White
  • Operates as part of the Ajax system or as a standalone device 
  • SmartBracket with an adjustable rotation angle

Even when it's fire without smoke

FireProtect 2 is equipped with two class A1R thermistors to detect smokeless fire threats. They give a significant advantage in detecting a rapid temperature rise when synthetic materials burn, or a fire starts from smoldering. Thermistors are located outside the enclosure to eliminate life-saving detection delays. So, FireProtect 2 AC is ready to detect a fire as fast as possible, even if it starts imperceptibly.

  • 10°C increase in temperature within a minute
  • Exceeding +64°C

Stable performance for a decade

The detector is powered by 110–240 V~ mains and has a sealed battery to serve as a backup. Even in a power outage, the detector keeps operating smoothly. Designed for the quick and reliable fire detection over its 10-year lifespan.

Always informed, everywhere

For residential fire alarm systems, informing people about fire danger is the priority. FireProtect 2 is equipped with a powerful 85 dB siren to eliminate the risk of missing an alarm. The detector uses impossible-to-ignore tones with different patterns to indicate an alarm or event, so it’s easy to recognize the type of threat and react accordingly.

Different sound and LED indications

  • Heat alarms
  • Malfunction
  • Low battery level
  • End of life

Enhanced wireless interconnection

All FireProtect 2 AC detectors can synchronously notify about the fire alarm in two ways: primary and fallback . In case of danger, the initiating detector sends a fire alarm to the hub. The hub initiates the primary interconnect: all fire detectors will activate the built-in sirens in 20 seconds — three times faster than the fire standard requires. All information is immediately available in Ajax apps: initiating detector’s location, alarm type, and exact time. If there is no connection with the hub, the initiating detector activates the fallback interconnection bydirectly sending the alarm to other fire detectors. It takes only 1 minute to raise an alarm.

Unleash the Ajax power

The Ajax smart and complex ecosystem brings new standards to the fire safety industry. FireProtect 2 is ready to protect your home without an Ajax hub but can do even more when connected to it. Intuitive Ajax apps provide remote setup and all detector information in real-time from anywhere the Internet is available, on a smartphone or PC. With instant notifications, there is no chance of missing a fire alert, and scenarios let you automate fire security to enhance home protection while you’re away. A complete set with stable wireless communication — essential reliability tested over the years by nearly two million users.

Full monitoring for the building

Data-rich notifications
The system instantly notifies about alarms with the critical alerts from the Ajax apps. Security companies and users know exactly which device triggered, when and where it happened. The system controls each device state and reports if there is a malfunction or it's time to replace the batteries.

Detailed event log
The event log records 500 recent events within the system. The data is explicit with the device, time, and description of the event. It helps reconstruct the actual event and find the causes to obtain comprehensive information for firefighters or an insurance company.

Monitoring with PRO Desktop

With PRO Desktop, building administration staff can observe not only security but Ajax fire detectors for instant reaction to alarms. Device statuses, event log, batteries data — the CMS operator has a complete picture in one intuitive interface, all informative and centralized. The installation engineer can remotely change the settings and provide services in time.

Advanced automation for greater safety

Ajax fire detectors are a part of the Ajax ecosystem and can interact with automation devices and PhOD detectors of the MotionCam lineup through scenarios. In the case of a fire alarm, the WallSwitch relay de-energizes the house, and Relay activates emergency lights. At the same time, MotionCam (PhOD) sends pictures into Ajax apps to identify the cause of the alarm. The result is a reliable combination of security and automation that works as a Swiss watch. 

Photo Evidence of fire Power supply control Electric lock unlocking
To quickly assess the situation at the protected facility and respond accordingly.
Fire detected > FireProtect 2 Jeweller > MotionCam (PhOD) Jeweller > Cause of fire
To cut off power to a possible source of fire and protect appliances from the consequences of firefighting.
Fire detected > FireProtect 2 Jeweller > WallSwitch Jeweller > Mains power cut > Relay Jeweller > Emergency lights activated
To speed up people's evacuation and ease firefighters' access to the building.
Fire detected > FireProtect 2 Jeweller > Relay Jeweller > Emergency exits unlocked

Unique wireless technologies

The Ajax system uses two-way secure radio communication based on the Jeweller proprietary protocol. It supports block cipher encryption and device authentication on every session with the hub to prevent sabotage, spoofing, or data theft.

 

  • Up to 1,700 m of radio communication with a hub
  • Encrypted two-way radio communication
  • Notifications about jamming and connection loss

Effortless installation and maintenance

FireProtect 2 AC is ready to operate straight out of the box. It takes only 90 seconds to install the detector with no need to disassemble the enclosure. The upgraded SmartBracket mounting panel now has the lever-actuated WAGO 221 connectors familiar to every industry expert. An installer can wire the power supply without a screwdriver, secure the detector on ceilings, and level it at 90° angles after mounting.

The device is paired with the hub by scanning the QR code in the Ajax apps. And it can always be reconfigured remotely without site visits. A self-test system automatically diagnoses sensors and reports their state to the hub. Testing can also be run manually anytime in the app or by pressing the detector front panel.

Connection Installations Setup Maintenance
Pairing with the hub via QR code
SmartBracket with the WAGO 221 connectors to secure the wires without screwdriver
Configuring and testing in the mobile or desktop apps
The dustproof smoke chamber that does not require cleaning

Attributes
Category Type Detector Sounder
Colour Black
Detection Heat
IP Rating IP20
System Type Domestic
Clearance No
Write Your Own Review
You're reviewing:Ajax FireProtect 2 AC (Heat) Jeweller - Black

Communication

Jeweller communication technology
Proprietary wireless communication technology to transmit commands, alarms, and events.
Key features:
Two-way communication.
Advanced sabotage protection.
Block encryption featuring a dynamic key.
Instant notifications.
Remote control and configuration in Ajax apps.
Frequency bands
866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Maximum effective radiated power (ERP)
up to 20 mW
Automatic power control to reduce power consumption and radio interference.
Radio signal modulation
GFSK
Radio communication range
up to 1,500 m
Between the device and control and indicating equipment (CIE) or a range extender in an open space.
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Frequency hopping
To prevent radio interference and jamming.

 

Sensitive elements

Sensitive element
Heat sensor

 

Heat detection

Sensitive element
according to the requirements for Class A1R heat detectors
Requirements of EN 54-5 and BS 5446-2 standards.
High temperature alarm
at temperatures above 64 °C
Temperature spike alarm
when the temperature rises more than 10 °C in 1 minute or less

 

 

Additional Features

In-built siren
volume 85 dB at a distance of 3 meters
Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.
Interconnected fire detectors alarms
via primary interconnection
If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps.
via fallback interconnection
At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub.
LED indication
green is a power indication
A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291.
yellow is an indication of malfunctions
A LED indicator on the device enclosure lights up when malfunctions are detected. For example, in the case of discharged batteries, contamination of the smoke chamber, or end of the service life.
red is an indication of fire alarms
A LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, the pressing turns off the detector sound notification.

 

Sabotage protection

Tamper Alarm
Alerts of attempts to detach the detector from the surface or remove the mounting panel.
Protection against spoofing
device authentication
Detection of communication failure
within 15 minutes
The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings). The polling interval is fixed at 300 seconds.

 

Power supply

Main 110–240 V~, 50/60 Hz
Up to 2 W of mains power consumption.
Backup
1 non-replaceable lithium battery CR-2/3AZ
Allows the detector to operate autonomously without the main power source.

 

Enclosure

Dimensions
122 x 122 x 54 mm
Weight
303 g
Operating temperature range
from 0 °C to +50 °C
Operating humidity
up to 80%
Protection class
IP20

 

Complete set

Contains FireProtect 2 AC (Heat) Jeweller
SmartBracket mounting panel
WAGO 221 3-conductor terminal — 2 pcs. (pre-installed in SmartBracket)
Installation kit
Quick start guide