Ajax FireProtect 2 SB (Heat/Smoke/CO) Jeweller - White

In stock
Product Code
52256.150.WH1
SKU
52256.150.WH1

Ajax FireProtect 2 SB (Heat/Smoke/CO) Jeweller - White

Wireless combined heat, smoke, and CO detector with sealed batteries

DELIVERY

We always aim to same day dispatch on all orders received before 2.30pm.

Read more about our delivery policy

TRADE COUNTER

Firesense also offer the ability to collect your order from our trade counter. 

Read more about our trade counter

FireProtect 2 SB (Heat/Smoke/CO) Jeweller

Wireless combined heat, smoke, and CO detector with sealed batteries

Product versions

FireProtect 2 RB (Heat/Smoke/CO) Jeweller FireProtect 2 SB (Heat/Smoke/CO) Jeweller
Up to 7 years of operation on replaceable batteries Up to 10 years of operation on sealed batteries

Accuracy through steam, dust, and time

FireProtect 2 (Heat/Smoke/CO) Jeweller is a battery-powered fire detector designed to protect homes without false alarms. Its dustproof and insect-resistant smoke chamber, dual-spectrum optical sensor, proprietary software algorithm, two thermistors, and a chemical carbon monoxide (CO) sensor deliver best-in-class detection accuracy. If danger is real, an 85 dB siren, two interconnection types, and instant push notifications in Ajax apps make the alarm impossible to ignore. With thoughtful design, self-monitoring, and early low battery alerts, the device ensures uninterrupted protection with fewer maintenance visits.

Key Features

  • Two types of interconnected fire alarm 
    • Primary via Ajax Hub, alarm within 20 s
    • Fallback via detector-detector, alarm within 60 s
  • Versions with different battery types
    • Replaceable
    • Sealed
  • Sensors
    • Heat
    • Smoke
    • CO
  • 85 dB built-in siren
  • Remote control and configuration 
  • Informative push notifications
  • Up to 1,700 m communication range with an Ajax hub in open space 
  • Jeweller radio communication 
  • Two colours 
    • Black
    • White
  • Operates as part of the Ajax system or as a standalone device 
  • SmartBracket with an adjustable rotation angle
  • Dual-spectrum optical smoke sensor to filter out false alarms
  • Dustproof and insect-resistant smoke chamber

Detection without compromise

Smoke detection
The detector is designed to ensure accurate smoke detection over time. A dustproof and insect-resistant smoke chamber features a dual-spectrum optical sensor. It uses blue and infrared LEDs to measure the concentration of combustion products and the size of their volatile particles. The HazeFlow 2 algorithm then analyzes the collected data to distinguish smoke from false triggers, such as vapor or steam. If the analysis indicates a real fire, the detector instantly raises an alarm.

Heat detection
FireProtect 2 (Heat/Smoke) Jeweller is equipped with two A1R-class thermistors to detect smokeless fires. Positioned outside the enclosure, the thermistors immediately register if the temperature rises by 10 °C within a minute or exceeds a threshold of +64 °C. This design ensures the fastest possible response, even when a threat grows gradually.

CO detection
CO is a highly poisonous yet colorless and odorless gas. Without a CO detector, it can build up unnoticed until poisoning occurs. Equipped with a chemical sensor, FireProtect 2 (Heat/Smoke/CO) Jeweller monitors the CO level and warns about dangerous concentrations before the first symptoms appear. The sensor ensures reliable CO detection for up to 10 years.

The detector is triggered if the CO level reaches:

  • 50 ppm in no more than 90 minutes
  • 100 ppm in no more than 40 minutes
  • 300 ppm in no more than 3 minutes

Stable performance for a decade

FireProtect 2 (Heat/Smoke/CO) Jeweller delivers up to 10 years of autonomous operation thanks to pre-installed batteries, sealed or replaceable. Real-time battery status is always visible in Ajax apps, so there is no need for unnecessary maintenance visits. If the battery runs low, users receive push notifications and on-site LED and sound alerts 30 days before the full discharge.

SB version
Up to 10 years of operation
on sealed batteries

RB version
Up to 7 years of operation
on replaceable CR123A batteries

Clear alerts for faster response

In addition to LED indication, FireProtect 2 (Heat/Smoke) Jeweller features impossible-to-ignore sound alerts, thanks to a powerful 85 dB siren with distinct tones. Each indication corresponds to a specific event, drawing attention and helping users react accordingly.

Sound and LED indications

  • Smoke or heat alarms
  • Dangerous CO level
  • Malfunction
  • Low battery
  • End of life

Enhanced wireless interconnection

To spread an alarm across the facility as quickly as possible, FireProtect 2 (Heat/Smoke) Jeweller supports primary and fallback1 interconnection with other on-site fire detectors. The primary one operates via a hub: the detectors alert the hub to a threat, which then activates the sirens of all fire detectors on-site. The process takes just 20 seconds — three times faster than standards require. If hub communication is lost, the fallback interconnection takes over. The initiating fire detector directly communicates with other devices, raising the alarm across the system within a minute. Even in the worst-case scenario, people on-site are warned and have time to act.

Advanced automation for greater safety

While FireProtect 2 Jeweller detectors can be used as standalone devices, they gain many more capabilities within a larger Ajax system. They can interact with automation devices and MotionCam (PhOD) Jeweller detectors via scenarios, triggering automated responses to fire alarms. This interaction helps enhance home protection when people are away or speed up evacuation when they are on site.

Photo Evidence of fire Power supply control Electric lock unlocking
To quickly assess the situation at the protected facility and respond accordingly.
Fire detected > FireProtect 2 Jeweller > MotionCam (PhOD) Jeweller > Cause of fire
To cut off power to a possible source of fire and protect appliances from the consequences of firefighting.
Fire detected > FireProtect 2 Jeweller > WallSwitch Jeweller > Mains power cut > Relay Jeweller > Emergency lights activated
To speed up people's evacuation and ease firefighters' access to the building.
Fire detected > FireProtect 2 Jeweller > Relay Jeweller > Emergency exits unlocked

Effortless installation and maintenance

FireProtect 2 (Heat/Smoke/CO) Jeweller is ready to operate straight out of the box. With no enclosure disassembly required and intuitive in-app setup, it can be up and running within minutes. Maintenance and testing are just as effortless thanks to the self-test feature, real-time device state, and remote configuration available in Ajax apps.

Connection Installations Setup Maintenance
Adding to the system via a QR code SmartBracket panel with a 90° rotation angle and no enclosure disassembly Configuration and testing in mobile and desktop Ajax apps Dustproof and insect-resistant smoke chamber that does not require cleaning
Attributes
Category Type Detector Sounder
Colour White
Detection Optical, Heat, Carbon Monoxide
IP Rating IP20
System Type Domestic
Clearance No
Write Your Own Review
You're reviewing:Ajax FireProtect 2 SB (Heat/Smoke/CO) Jeweller - White
Your Rating

Communication

Jeweller communication technology
Proprietary wireless communication technology to transmit commands, alarms, and events.
Key features:
Two-way communication.
Advanced sabotage protection.
Block encryption featuring a dynamic key.
Instant notifications.
Remote control and configuration in Ajax apps.
Frequency bands
866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Maximum effective radiated power (ERP)
up to 20 mW
Automatic power control to reduce power consumption and radio interference.
Radio signal modulation
GFSK
Radio communication range
up to 1,700 m
Between the device and control and indicating equipment (CIE) or a range extender in an open space.
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Frequency hopping
To prevent radio interference and jamming.

 

Sensitive elements

Sensitive element
smoke sensor
heat sensor
CO (carbon monoxide) sensor

 

Smoke detection

Sensitive element
double-spectrum optical sensor
Recognizes smoke by the size of particles in the air.
Protection from false alarms
Does not react to water vapor.
Patented smoke chamber
Protects the smoke sensor from dust, dirt, and insects.

 

Dangerous temperature detection

Sensitive element
according to the requirements for Class A1R heat detectors
Requirements of EN 54-5 and BS 5446-2 standards.
High temperature alarm
at temperatures above 64°C
Temperature spike alarm
when the temperature rises more than 10°C in 1 minute or less

 

Carbon monoxide (CO) detection

Sensitive element
chemical CO sensor
Alarm if accumulated dose of CO is exceeded
more than 50 ppm (0.005%) — no more than in 90 minutes
more than 100 ppm (0.01%) — no more than in 40 minutes
more than 300 ppm (0.03%) — no more than in 3 minutes
CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute.
Sensor life
10 years
After 10 years of operation, the detector must be replaced with a new one.

 

 

Additional Features

In-built siren
volume 85 dB at a distance of 3 meters
Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.
Interconnected fire detectors alarms
via primary interconnection
If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps.
via fallback interconnection
At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub.
LED indication
green is a power indication
A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291.
yellow is an indication of malfunctions
A LED indicator on the device enclosure lights up when malfunctions are detected. For example, in the case of discharged batteries, contamination of the smoke chamber, or end of the service life.
red is an indication of fire alarms
A LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, the pressing turns off the detector sound notification.

 

Sabotage protection

Tamper Alarm
Alerts of attempts to detach the detector from the surface or remove the mounting panel.
Protection against spoofing
device authentication
Detection of communication failure
within 15 minutes
The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings). The polling interval is fixed at 300 seconds.

 

Power supply

Battery
2 non-replaceable lithium batteries
10 years of battery life.

 

Enclosure

Dimensions
124 × 124 × 45 mm
Weight
274.5 g
Operating temperature range
from 0 °C to +50 °C
Operating humidity
up to 80%
Protection class
IP20

 

Complete set

Contains FireProtect 2 SB (Heat/Smoke/CO) Jeweller
SmartBracket mounting panel
Installation kit
Quick Start Guide