C-TEC XFP 1 Loop, 32 Zone, Apollo Protocol
XFP 1 Loop, 32 Zone, Addressable Fire Alarm Panel, Apollo Protocol
DELIVERY
We always aim to same day dispatch on all orders received before 2.30pm.
TRADE COUNTER
Firesense also offer the ability to collect your order from our trade counter.
C-TEC’s XFP single loop 32 zone addressable fire alarm panel offers high performance at a very competitive price.
LPCB certified to EN54 parts 2 & 4, it is supplied in durable metal enclosure, offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollo's XP95/Discovery protocol.
Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels, it is one of Europe's best-selling addressable fire panels.
Packed full of engineering features - please refer to the feature list below - the XFP501/X is also fully compatible with C-TEC’s Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs
C-TEC’s XFP single loop 32 zone addressable fire alarm panel offers high performance at a very competitive price.
LPCB certified to EN54 parts 2 & 4, it is supplied in durable metal enclosure, offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollo’s XP95/Discovery protocol.
Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels, it is one of Europe’s best-selling addressable fire panels.
Packed full of engineering features – please refer to the feature list below – the XFP501/X is also fully compatible with C-TEC’s Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.
Features
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Optional flush-mounting bezel and glazed stainless steel enclosure also available.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
| Approval | EN54-2, EN54-4 |
|---|---|
| Category Type | Panel |
| Colour | Grey |
| IP Rating | IP30 |
| System Type | Addressable |
| Clearance | No |
| Approvals/certifications | Certified to EN54-2 & 4 by the LPCB |
| Protocol/compatibility | Apollo/XP95/Discovery |
| Mains supply | 230V 50/60Hz |
| Mains rated current | 680mA maximum |
| Internal power supply | 27VDC nominal |
| Total output current limited to | 3A @ 230VAC (lmax.A 250mA; lmin 70mA) |
| Quiescent current | 80mA (Loop unloaded) |
| Max battery size and type | 2 x 12V 7Ah VRLA connected in series |
| No. of loop drivers | 1 |
| Max loop output current | 500mA (25V min; 34V max) |
| Max loop length | 1KM |
| Max addressable devices per loop | 126 |
| No. of conventional sounder circuits | 2 (max length per circuit is 500m) |
| EOL resistor value | 6800Ω 5% Tol. 0/25W (blue, grey, red, gold) |
| Max sounder output current | 400mA |
| Auxiliary relays | 3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc |
| Other outputs | 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA. |
| Auxiliary inputs | 2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching). |
| PC Connection | PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available |
| Indicators | 2 line x 40 character backlit display; 32 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault |
| Connections | Fixed, largest acceptable conductor size 1mm2 |
| Expansion connections | 2-wire RS485 non-redundant network/repeater connection available via optional AFP711 network card. Max. 8 mains per network (Limit 1KM.) or 8 repeaters per non-networked main. |
| Product dimensions (mm) | 410 W x 250 H x 80 D (base); 439 W x 274 H x 7 D (lid) |
| Construction and finish | Metal |
| IP Rating | IP30 |
| Weight | 4.5Kg (without batteries) |
| Operating conditions/temperature | -5°C to +40°C. Max relative humidity: 95% |