Haes XL32-24

In stock
Product Code
XL32-24
SKU
HA8024

Haes Esento Evoque 24 Zone Conventional Control Panel

Esento Evoque 24 Zone Conventional Control Panel

DELIVERY

We always aim to same day dispatch on all orders received before 2.30pm.

Read more about our delivery policy

TRADE COUNTER

Firesense also offer the ability to collect your order from our trade counter. 

Read more about our trade counter

Haes XL32-24

24 zone Esento Evoque fire alarm control panel. Evoque panels are our large zone format range and provide a generous selection of programmable features, inputs and outputs. Fully networkable up to 8 control panels, 3 false alarm management modes and fully functional repeater panels. (N.B. No Twin Wire mode)

Features:

  • 24 zones
  • Zonal Twin Wire selection by DIL switch
  • Network up to 8 control panels
  • Activate controls via key switch or code entry
  • Integral detector removal monitoring
  • 5 Amp switch mode power supply Nom 27V DC
  • 4 monitored sounder outputs
  • 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free
  • Class change I/P
  • Alert I/P
  • Fire & fault switched -ve outputs
  • Program delays to outputs
  • False alarm modes A, B & C
  • Test mode, with or without sounders
  • Disable zones, sounder O/Ps, aux O/Ps & delays
  • Alarm load, 4.25A shared between all sounder outputs
  • All sounder circuits are fused @ 500mA with resettable fuses
Attributes
Approval LPCB
Category Type Panel
Colour Grey
IP Rating IP30
System Type Conventional
Clearance No
Write Your Own Review
You're reviewing:Haes Esento Evoque 24 Zone Conventional Control Panel
Your Rating

Specifications

Enclosure
1.2mm Mild Steel IP30. Colour ref: MW334E Interpon powder coat
Cable Entry
Via 20mm knockouts located in the top and rear of the cabinet
Dimensions
Back box: 450mm W x 400mm H x 130mm D, Lid: 465mm W x 410mm H x 25mm D
Mains Supply
5A internal switch mode power supply, Nom 27v DC
Battery Capacity
2 x 18Ah 12v VRSLA
Detection Zones
24 x conventional. EOL = 4K7
Sounder Circuits 4 x monitored, fused @500mA. EOL = 4K7R
Networking Up to 8 control panels, fault tolerant RS485 communication, requires TPCA05 network card
On Board Relays 2 x programmable, 3A, 30v volt free changeover, additional relay provided on high spec zone card
Programmable Outputs 4 x programmable 40mA switch -ve outputs
Switch Inputs Class change & alert (pulsing)
Event Log 40 event history
Intrinsically Safe Mode Selectable per zone
False Alarm Management Type A, B & C dependency modes, approved by LPCB
Delay Timer On board programmable delay timer 1-10 mins